Procedure
Procedure
Place the server on a flat, level surface with the access panel facing up.

Remove the access panel

Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components
WARNING:
to cool before touching them.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning
CAUTION:
any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION:
CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner
results in improper airflow and improper cooling that can lead to thermal damage.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If installed, unlock and remove the security padlock and/or Kensington security lock.
For more information, see the lock documentation.
5. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
6. Remove the front bezel .