Removing And Replacing The Emi Shield - HPE ProLiant ML30 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Disconnect the front USB 3.0 ports cable from the system board.
9. Remove the front panel USB ports cable:
a. Remove the screws.
b. Remove the front panel USB ports cable from the front panel.
To replace the component, reverse the removal procedure.

Removing and replacing the EMI shield

Removing and replacing the EMI shield
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
CAUTION:
with either a component or a blank.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide
51