HPE ProLiant ML30 Gen10 Maintenance And Service Manual page 42

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Back up all server data on the drive.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
6. Remove the front bezel .
7. Remove the access panel .
8. If installed, remove the air baffle .
9. Disconnect all cables from the drive .
10. Remove the non-hot-plug drive cage:
a. Remove the screws.
Retain the screws for future use.
b. Remove the drive cage.
11. Remove the drive:
a. Remove the screws securing the drive.
Retain the screws for future use.
b. Slide the drive out of the drive cage.
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide