To replace the component, reverse the removal procedure.

Removing and replacing a heatsink

Removing and replacing a heatsink
Removing a heatsink
Removing a heatsink
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components
WARNING:
to cool before touching them.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Allow the heatsink to cool.