3. Install the heatsink:
a. Position the heatsink on the processor backplate.
b. Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c. Finish the installation by completely tightening the screws in the same sequence.
d. Connect the heatsink fan cable .
CAUTION: The fan does not have a fan guard. Special attention is needed when removing or installing the
CAUTION:
heatsink to prevent finger injury.
4. If removed, install the air baffle.
5. Install the access panel.
6. Install the front bezel.
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide