HPE ProLiant ML30 Gen10 Maintenance And Service Manual page 83

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Locate the battery on the system board .
9. Remove the system battery:
a. Use a small flat-bladed, nonconductive tool to press the battery latch (callout 1).
b. Remove the system battery from the socket (callout 2).
10. Install the system battery:
a. With the side of the battery showing the "+" sign facing up, insert the battery into the socket (callout 1).
b. Press the system battery down until it clicks into place (callout 2).
11. Install the access panel .
12. Install the front bezel .
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide
83