To replace the component, reverse the removal procedure.
Removing and replacing the M.2 SSD/dedicated iLO/serial port enablement board
Removing and replacing the M.2 SSD/dedicated iLO/serial port enablement board
CAUTION:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an
expansion slot cover or an expansion board installed.
CAUTION:
CAUTION:
Before replacing a DIMM, expansion card, or other similar PCA components due to a perceived hardware error, make
sure first that the component is firmly seated in the slot. Do not bend or flex circuit boards when reseating components.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following tools available:
T-15 Torx screwdriver
Phillips No. 1 screwdriver
4.5 mm hex nut screwdriver
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide