System Battery Replacement; System Battery Information; Removing And Replacing The System Battery - HPE ProLiant ML30 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

To replace the component, reverse the removal procedure.

System battery replacement

System battery replacement

System battery information

System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery that provides power to the
real-time clock. If this battery is not properly handled, a risk of the fire and burns exists. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not expose the battery to extremely low air pressure as it might lead to explosion or leakage of flammable liquid or gas.
Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
If the server no longer automatically displays the correct date and time, then replace the battery that provides power to the real-
time clock. Under normal use, battery life is 5 to 10 years.

Removing and replacing the system battery

Removing and replacing the system battery
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide
82

Advertisement

Table of Contents
loading

Table of Contents