Removing and replacing a PCI fan

Removing and replacing a PCI fan
NOTE: A PCI fan is also required while the server is in rack mode.
NOTE:
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Remove the PCI fan module:
a. Disconnect and release the fan cable from the metal tab.
b. Remove the screws.
c. Remove the PCI fan.
To replace the component, reverse the removal procedure.