To replace the component, reverse the removal procedure.

Removing and replacing an M.2 SSD

Removing and replacing an M.2 SSD
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Remove the M.2 SSD:
a. Remove the SSD mounting screw.
b. Lift the M.2 SSD at an angle of 45°.
c. Remove the M.2 SSD from the M.2 SSD slot.
To replace the component, reverse the removal procedure.