Installation
For HEX-E/H QC
Then route the Tool data cable to the Compute Box (CB) and use the supplied Velcro tape (black) to fix it.
NOTE:
Make sure that during the routing some extra length is used at the joints
so that cable is not pulled when the robot moves.
Also make sure that the cable bending radius is minimum 40mm (for the
HEX-E/H QC it is 70mm)
Finally, connect the other end of the Tool data cable to the Compute Box's DEVICES connector.

4.3.2 Ethernet cable

Connect one end of the supplied Ethernet (UTP) cable to the robot controller's Ethernet (LAN) port.
NOTE:
If the robot controller's Ethernet port is in use, use a standard 4-port
Ethernet switch to be able to use two network devices at the same time.
Connect the other end of the supplied cable to the Compute Box's ETHERNET connector.
Use the marked M12-12pin connector on the HEX-E/H QC.
CAUTION:
Use only original OnRobot tool data cables.
Do not cut or extend these cables.
CAUTION:
Quick Changer and Dual Quick Changer can
only be used to power OnRobot tools.