Pg Extension Card Function Description; Uvw Incremental Pg Card--Hd2-E - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series Inverter
Electrical connection:
The PROFINET communication card adopts a standard RJ45 interface, which can be used in
a linear network topology and a star network topology. The linear network topology electrical
connection diagram is shown below.
Master
device
Linear network topology electrical connection diagram
Note: For the star network topology, users need to prepare PROFINET switches.
The star network topology electrical connection diagram is shown below:
Master
device
A.7 PG extension card function description
A.7.1 UVW incremental PG card––HD2-E-PGI
The terminals are arranged as follows:
PE
AO
+
GN
AO-
D
Slave device 1
RJ45
RJ45
Slave device 1
RJ45
RJ45
BO
ZO+
A1+
+
BO-
ZO-
A1-
Slave device 2
RJ45
RJ45
Slave device 2
RJ45
RJ45
A2+
A2-
B1
Z1+
+
B1-
Z1-
-306
Slave device n
RJ45
RJ45
Slave device n
RJ45
RJ45
B2
B2-
Z2+
+
U+
V+
W+
U-
V-
W-
Z2-
PWR
PGN
D