Multi-Step Speed Running - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series
Function
code
P10.35
P17.00
P17.27
Actual stage of simple PLC

Multi-step speed running

5.5.14
Set the parameters used in multi-step speed running. the HD2 IP55 series inverter can set 16-
step speeds, which are selectable by multi-step speed terminals 1–4, corresponding to multi-
step speed 0 to multi-step speed 15.
Related parameter list:
Function
code
P05.01–
P05.06
Name
Acceleration/deceleration
time of 8–15 stage of
simple PLC
Set frequency
Name
Digital input function
selection
Description
0x0000–0XFFFF
0.00Hz–P00.03 (max. output frequency)
Displays the present stage of the simple
PLC function.
Description
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
-95-
Basic Operation Instructions
Default
value
0000
0.00Hz
Default
value
0

Advertisement