HD2 IP55 High-ingress Protection Series Inverters
key or
key is pressed without selecting addition operation, it will return to parameter setup
list menu.
All the function code groups under parameter setup sub-menu can be added to "common
parameter setup" list. Up to 64 function codes can be added to the "common parameter setup"
list.

5.4.5 Parameter selection edit interface

In the fourth-level menu of "parameter setup" menu, press
to enter parameter selection edit interface. After entering edit interface, current value will be
highlighted. Press
corresponding parameter item of current value will be highlighted automatically. After parameter
selection is done, press
the previous menu. In parameter selection edit interface, press
parameter value and return to the previous menu.
In parameter selection edit interface, the "authority" on the top right indicates whether this
parameter is editable or not.
"√" indicates the set value of this parameter can be modified under current state.
"×" indicates the set value of this parameter cannot be modified under current state.
"Current value" indicates the value of current option.
"Default value" indicates the default value of this parameter.

5.4.6 Parameter setup edit interface

In the fourth-level menu in "parameter setup" menu, press
to enter parameter setup edit interface. After entering edit interface, set the parameter from low
bit to high bit, and the bit under setting will be highlighted. Press
increase or decrease the parameter value (this operation is valid until the parameter value
exceeds the max. value or min. value); press
parameters are set, press
previous parameter. In parameter setup edit interface, press
parameter value and return to the previous menu.
key and
key or
Figure 5-15 Parameter selection edit interface
Current value
0
0:SVC 0
1:SVC 1
2:V/F mode
3:VC mode
Return
key or
key to edit current parameter value, and the
key to save the selected parameter and return to
Default value:2
Authority:√
Homepage
Confirm
or
key to save the set parameters and return to the
-41-
Basic Operation Instructions
key,
key or
key to maintain the
Default value:2
Current value:
1
1:SVC 1
2:V/F mode
3:VC mode
Return
Homepage
key,
key or
key or
to shift the edit bit. After
to maintain the original
key
Authority:√
Confirm