P05 Group--Input Terminals - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series
P05 group––Input terminals
Function
code
HDI input
P05.00
Function of
P05.01
S1 terminal
Function of
P05.02
S2 terminal
Function of
P05.03
S3 terminal
Function of
P05.04
S4 terminal
Function of
P05.05
HDIA terminal
Function of
P05.06
HDIB terminal
Name
0x00–0x11
Ones: HDIA input type
0: HDIA is high-speed pulse input
1: HDIA is digital input
type
Tens: HDIB input type
0: HDIB is high-speed pulse input
1: HDIB is digital input
0: No function
1: Forward running
2: Reverse running
3: 3-wire control
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease setting
13: Switch-over between setup A and setup B
14: Switch-over between combination setup and
setup A
15: Switch-over between combination setup and
setup B
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: Acceleration/deceleration time selection 1
22: Acceleration/deceleration time selection 2
23: Simple PLC stop reset
24: Simple PLC pause
25: PID control pause
26: Wobbling frequency pause
27: Wobbling frequency reset
28: Counter reset
29: Switch-over between speed control and
torque control
30: Acceleration/deceleration disabled
31: Counter trigger
32: Reserved
33: Clear frequency increase/decrease setting
temporarily
Description
-141-
Function parameter list
Default
Modify
value
0
1
4
7
0
0
0

Advertisement

Table of Contents