Analog Output - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series
Function
code
P05.46
P05.47
P05.48
HDIB frequency input filter
P05.49
P05.50

5.5.10 Analog output

The HD2IP series inverter carries one analog output terminal (0–10V/0–20mA) and one high-
speed pulse output terminal. Analog output signals can be filtered separately, and the
proportional relation can be adjusted by setting the max. value, min. value, and the percentage
of their corresponding output. Analog output signal can output motor speed, output frequency,
output current, motor torque and motor power at a certain proportion.
AO output relationship description:
(The min. value and max. value of the output correspond to 0.% and 100.00% of the pulse or
analog default output. The actual output voltage or pulse frequency corresponds to the actual
percentage, which can be through function codes.
Set value
0
Name
Corresponding setting of
lower limit frequency of
HDIB
Upper limit frequency of
HDIB
Corresponding setting of
upper limit frequency of
HDIB
time
AI1 input signal type
Function
Running frequency
Description
-300.0%–300.0%
P05.45 –50.000kHz
-300.0%–300.0%
0.000s–10.000s
0–1
0: Voltage type
1: Current type
0–Max. output frequency
-79-
Basic Operation Instructions
Default
50.000kHz
100.0%
0.030s
Description
value
0.0%
0