Start/Stop Control - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series
Function
code
P12.05
P12.06
P12.07
P12.08
P12.09
P12.10
P12.15
P12.16
P12.17
P12.18
P12.19
P12.20
P12.21
Quadrature-axis inductance
P12.22
P12.23

5.5.7 Start/Stop control

The start/stop control of the inverter is divided into three states: start after running command at
power-up; start after restart-at-power-cut function is effective; start after automatic fault reset.
Descriptions for these three start/stop control states are presented below.
There are three start modes for the inverter, which are start at starting frequency, start after DC
brake, and start after speed-tracking. Users can select the proper start mode based on field
conditions.
For large-inertia load, especially in cases where reversal may occur, users can choose to start
after DC brake or start after speed-racking.
Note: It is recommended to drive synchronous motors in direct start mode.
Name
Rated current of
asynchronous motor 2
Stator resistance of
asynchronous motor 2
Rotor resistance of
asynchronous motor 2
Leakage inductance of
asynchronous motor 2
Mutual inductance of
asynchronous motor 2
No-load current of
asynchronous motor 2
Rated power of
synchronous motor 2
Rated frequency of
synchronous motor 2
Number of pole pairs of
synchronous motor 2
Rated voltage of
synchronous motor 2
Rated current of
synchronous motor 2
Stator resistance of
synchronous motor 2
Direct-axis inductance of
synchronous motor 2
of synchronous motor 2
Counter-emf constant of
synchronous motor 2
Description
0.8–6000.0A
0.001–65.535Ω
0.001–65.535Ω
0.1–6553.5mH
0.1–6553.5mH
0.1–6553.5A
0.1–3000.0kW
0.01Hz–P00.03 (max. output frequency)
1–50
0–1200V
0.8–6000.0A
0.001–65.535Ω
0.01–655.35mH
0.01–655.35mH
0–10000
-67-
Basic Operation Instructions
Default
value
50.00Hz
Depend
on model
Depend
on model
Depend
on model
Depend
on model
Depend
on model
2
300