Programmable Extension Card (Hd2-E-Plc) Function Description - IMO HD2 IP Series Instruction Manual

Ip55 high ingress protection
Table of Contents

Advertisement

HD2 IP55 High-ingress Protection Series
Category
Digital
input/output
Relay output
A.5 Programmable extension card (HD2-E-PLC) function description
The terminals are arranged as follows:
SW1 is the start/stop switch of the programmable expansion card. CN1 contains terminals PE,
485-, 485+, GND, AI1, and AO1, and a selection jumper resides on the next. "AI" and "AV" are
the current type input selection and voltage type input selection of AI1, and they can be selected
through J2. "AIO" and "AVO" are the current type output selection and voltage type output
selection of AO1, and they can be selected through J5. "120" indicates 120Ω terminal resistor,
and it can connect to J1. By default, J1 connects to NC, J2 to AV, and J5 to AVO.
PE
COM
PW
Indicator definition:
Indicator
LED1
Label
S5—COM
Digital input 1
S6—COM
Digital input 2
S7—COM
Digital input 3
S8—COM
Digital input 4
Y2—CME
Digital output
RO3A
NO contact of relay 3
RO3B
NC contact of relay 3
Common contact of
RO3C
RO4A
NO contact of relay 4
Common contact of
RO4C
485-
485+
COM
PS1
24V
PS4
Name
Power indicator (Green)
Name
1. Internal impedance: 3.3 kΩ
2. Power input range: 12–30 V
3. Bidirectional input terminal
4. Max. input frequency: 1 kHz
1. Switch capacity: 50 mA/30 V
2. Output frequency range: 0–1 kHz
3. The terminals CME and COM are
shorted through J3 before delivery.
1. Contact capacity: 3A/AC 250 V, 1 A/DC
30 V
relay 3
2. Do not use them as high-frequency
digital outputs.
relay 4
AI1
AO1
PS2
PS3
PS5
PS6
This indicator is on when the expansion card is
powered on.
-297-
Extension cards
Function description
PRO2A
PRO2C
PRO1A
Function
PRO1C

Advertisement

Table of Contents
loading

Table of Contents