Dc Output - NF DP015S Instruction Manual

Dp series programmable ac power source
Hide thumbs Also See for DP015S:
Table of Contents

Advertisement

*10: For the capacitor input type rectified load (crest factor=4), the rated output voltage, and 45 Hz
to 65 Hz.
*11: In the case that the power input is 170 V or lower, models with 6 kVA or higher have the limit
on the power capacity.
*12: For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum
current, and the operating temperature.
*13: For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*14: Set for the L1 phase. The component of the phase angle setting is added for the other phases.
*15: In the case of 50 V or higher, sine wave, and same load condition and voltage setting for all
phases.
*16: In the case of the AC mode and 23 °C±5 °C.
10.6

DC Output

Only single-phase model and single-phase output of the Multi-phase model. [V]=Vdc, [A]=Adc, the
power input voltage is 200 V, and the polarity is relative to the Lo terminal, unless otherwise noted.
Mode
Rated output
voltage
Voltage setting
range
Setting
resolution
Voltage accuracy
*17
Maximum current
*18
Maximum
instantaneous
current
*19
Power capacity
*20
*17: In the case of −212 V to −10 V, +10 V to +212 V/−424 V to −20 V, +20 V to +424 V, no load,
AC setting 0 V, 23°C±5°C.
*18: If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. If there is the AC superimposition, the active current of DC+AC satisfies the
maximum current. In the case that the ambient temperature is 40°C or higher, the maximum
current may decrease.
*19: Instantaneous = within 2 ms, at the rated output voltage
*20: In the case that the power input is 170 V or lower, models with 6 kVA (6 kW) or higher have
the limit on the power capacity.
DP Series
Single-phase model and Single-phase output of Multi-phase model
045S
015S
030S
045M
Floating output, the Lo terminal can be grounded.
−220 V to +220 V / −440 V to +440 V
15 A /
30 A /
45 A /
7.5 A
15 A
22.5 A
Peak value which is four times of the maximum current (Apk)
1.5 kW
3 kW
4.5 kW
060S
075S
100 V / 200 V
0.1 V
± (|1% of set| + 0.6 V / 1.2 V)
60 A /
75 A /
30 A
37.5 A
6 kW
7.5 kW
10.6 DC Output
090S
105S
120S
090M
90 A /
105 A /
120 A /
45 A
52.5 A
60 A
9 kW
10.5 kW
12 kW
247

Hide quick links:

Advertisement

Table of Contents
loading