Procedure To Connect To MDFs
Acquire two additional MDFs (MDFs 2 and 3).
Step 1.
Connect the RJ-11 connector ends of telephone wires you want for ADSL service to the USER ports
Step 2.
on the AAM1008.
Connect the other ends of the telephone wires to the upper ports of MDF 3 using a punch-down tool.
Step 3.
Connect the telephone wiring from the end-user's ADSL modem(s) to the lower ports of MDF 3.
Step 4.
Connect the RJ-11 connector ends of telephone wires you want for phone service to the AAM1008
Step 5.
ports labeled CO.
Connect the other ends of the telephone wires to the lower ports of MDF 2 using a punch-down tool.
Step 6.
Connect the upper ports of MDF 2 to the lower ports of MDF 1 using regular telephone wires.
Step 7.
Connect the upper ports of MDF 1 to the telephone company.
Step 8.
Telephone subscribers only (that is, non-ADSL subscribers) retain connections to the lower ports of
Step 9.
MDF 1.
Change the wiring from MDF 1 to MDF 3 for telephone subscribers who want ADSL service.
Step 10.
Hardware Connections

Figure 6-9 Installation Scenario B

IES-1000 User's Guide
6-9