37.11 Ethernet Port - ZyXEL Communications IES-1000 User Manual

Integrated ethernet switch
Hide thumbs Also See for IES-1000:
Table of Contents

Advertisement

STEPS
3
If you are attempting to telnet from the DSL side of the network module, refer to section 37.2 to make
sure that you can transmit data to the network module.
4
If you are attempting to telnet from the Ethernet side of the network module, check the Ethernet cable.
5
Make sure that the network module's IP settings are configured properly (refer to Chapter 33 ).
If these steps fail to correct the problem, contact the distributor.

37.11 Ethernet Port

Use the following commands if the Ethernet port connection repeatedly goes down without any logical
explanation.
37.11.1
Ethernet Device Driver Test Command
Syntax:
192.168.1.1 edd> test <ip>
where
<ip> =
The IP address of the device that you want the Ethernet port to continuously ping. Use
0.0.0.0 to stop the test.
The test command sets the network module's Ethernet port to ping the specified IP address every ten seconds. If
there is no ping response after the timeout period expires (see the
performs a physical reset on the network module's Ethernet port.
37.11.2
Ethernet Device Driver Set Timeout Command
Syntax:
192.168.1.1 edd>
where
<# of minutes>
The set timeout command sets how long the IES-1000 is to wait for a response to a test ping before
performing a physical reset on the network module's Ethernet port.
Troubleshooting
Table 37-10 Troubleshooting Telnet
CORRECTIVE ACTION
set timeout <# of minutes>
= The number of minutes you want the IES-1000 to wait for a response to a test
ping. The default number of minutes is 30 and the minimum is 1.
command), the IES-1000
set timeout
IES-1000 User's Guide