IES-1000 User's Guide
LABEL
Port Setup
Click this link to go to the Port Setup screen.
N-wire Group
Type a name to identify this n-wire group.
Name
Mode
Select how many wires to physically bundle together into an N-wire group and which side of
the connection this n-wire group is. Each port uses two wires so a 4-wire group consists of
two ports and an 8-wire group consists of four ports. For example, 4-wireSTU-C means two
ports on the SHDSL Terminal Unit – Central side. 8-wireSTU-R means four ports on the
SHDSL Terminal Unit – Remote side.
You can bundle multiple groups of ports as long as they do not overlap. One SAM1008
module can have both STU-C and STU-R groups.
Make sure that G.SHDSL ports one through four are all the same end of their connections (all
STU-C or all STU-R).
Make sure that G.SHDSL ports five through eight are all the same end of their connections (all
STU-C or all STU-R).
G.SHDSL ports one through four do not need to be set to be the same end of the connection
as G.SHDSL ports five through eight. For example, G.SHDSL ports one through four could be
set to be STU-C while G.SHDSL ports five through eight are set to be STU-R.
Group Number
Select which ports are to be members of this bundled n-wire group.
With a 4-wire group, select 4 for ports seven and eight, 3 for ports five and six, 2 for ports
three and four or 1 for ports one and two.
You must configure 4-wire group 4 before group 3 and group 2 before group 1.
Although you can configure groups 2 and 1 before configuring groups 4 and 3, it is
recommended that you configure 4-wire groups from right to left (higher numbers to lower
numbers) and delete them from left to right (lower numbers to higher numbers).
With an 8-wire group, select 2 for ports five to eight or 1 for ports one to four.
Apply
Click Apply to save your changes back to the IES-1000's volatile memory. The IES-1000
loses these changes if it is turned off or loses power, so use the Config Save link in the
navigation panel on the left to save your changes to the non-volatile memory when you are
done configuring.
Reset
Click Reset to begin configuring this screen afresh.
12.8.5
Add G.SHDSL Port Bonding
Click Add in the Port Setup screen (under the port bonding table) to go to the Add G.SHDSL Port Bonding