ZyXEL Communications IES-1000 User Manual page 166

Integrated ethernet switch
Hide thumbs Also See for IES-1000:
Table of Contents

Advertisement

IES-1000 User's Guide
LOG MESSAGE
GSHDSL <port> Link
Info: NM=<noise
margin> ATT=<loop
attenuation>
GSHDSL <port> Link
Up(SN=<seq no>):
rate=<rate>Kbps
GSHDSL <port> Link
Down(SN=<seq no>)
NM=<noise margin>
ATT=<loop attenuation>
GSHDSL <port> CRC
crcAnomaly:<couter1>
LOSW Defect:<couter2>
LOSW Failure:<couter3>
GSHDSL <port> ATT
Defect:<couter1> SNR
Defect:<couter2>
HTTPD data crash
theAllegroServerDataPt
r <mem addr>
File too large <file
id> <file size>
Insecure HTTP From <ip
addr>
Watchdog timeout
Warm Start Trap
Cold Start Trap
Core Dump!!!
THERMO OVER RANGE:
dev:<device id>
value:<temp>
20-4
Table 20-3 Log Messages
TYPE
INFO
This log displays information about a G.SHDSL port's connection.
<port>
<noise margin> - the connection's signal quality in dB.
<loop attenuation> - the connection's line loss in dB.
WARN
A G.SHDSL port established a connection.
<seq no>
<rate> - the connection's rate
WARN
A G.SHDSL port lost its connection.
WARN
These are G.SHDSL port error counters.
<couter1>- the number of cyclic redundancy check errors
<couter2> - the number of Loss of Sync Word defects
<couter3> - the number of Loss of Sync Word failures
WARN
These are G.SHDSL port error counters.
<couter1> - the number of times the loop attenuation was too
high
<couter2> - SNR (Signal to Noise Ratio) the number of times the
signal quality was too low.
ERROR
The network module failed in an attempt to construct an HTTP (web
configurator) session.
WARN
The file size was too large with an attempted HTTP (web
configurator) firmware upload.
WARN
Someone tried to start an HTTP (web configurator) session from the
listed IP address and it did not match any of the configured secured
client IP addresses.
WARN
The hardware watchdog determined that the network module was
hung or not executing the correct sequence of code and restarted the
network module.
WARN
The network module restarted as a result of a reboot command.
WARN
The network module started.
WARN
The error log is not kept after a restart. When the network module
restarts due to a software level error, you can use config save in
order to create a core file. Send the core file to customer support for
analysis.
WARN
The temperature detected in the network module was too high.
<temp>
DESCRIPTION
- port number
- sequence number of the connection
- temperature when the entry was logged
Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ies-1000mIes-1000 - v2.05

Table of Contents