FIELD
Active
The factory default of all VDSL ports is disabled. A port must be enabled for data
transmission to occur. Press [SPACE BAR] to select Yes and press [ENTER] to
enable the specified VDSL port.
Type
This read-only (r.o.) field displays the type of port you are currently configuring.
(Ethernet Ports 13 and 14 relate to the VES-1012 only).
VDSL Mode
VDSL mode can be configured per port. Press [SPACE BAR] and then press
[ENTER] to choose from 10BaseS, ETSI Plan 997, ANSI/ETSI Plan 998 or
Special_Mode.
Speed:
Rate Adaption Press [SPACE BAR] once to select Yes (if not already selected) and then press
[ENTER] to enable rate adaption.
To view the actual DSL transmission rate attained on the VDSL line, enter 24 from
the main menu, then enter 1 to open Menu 24.1 — System Status and finally
enter 1 again to open Menu 24.1.1 — System Maintenance — System Status.
Max. Upstream Press [SPACE BAR] to cycle through the upstream speeds. Speeds available
depend on the VDSL Mode chosen in Menu 2 – Switch Setup.
Max.
Press [SPACE BAR] to cycle through the downstream speeds available for the
Downstream
VDSL Mode chosen in Menu 2 – Switch Setup.
Edit Filter
Press [SPACE BAR] once to select Yes and then press [ENTER] to go to Menu
6.1.4 – Edit Filter.
Edit Spanning
Press [SPACE BAR] once to select Yes and then press [ENTER] to go to Menu
Tree Protocol
6.1.1 - Port Spanning Tree Protocol Setup. You must enable STP on the switch
Setup
(in menu 2) before you configure it on a port(s). Note that you very rarely need to
enable STP on VDSL ports since the VDSL ports are directly connected to the
users.
Edit VLAN
You only see this field if you've selected 802.1Q VLAN Type in menu 2. Press
Setup
[SPACE BAR] once to select Yes and then press [ENTER] to open Menu 6.1.3 —
Port VLAN Setup.
Default Port
The Default Port Priority value is added to incoming frames without a (802.1p)
Priority
priority tag. The default is 0. Use this field to define the default priority of each
port.
Limiting number
Use this field to limit the number of (dynamic) MAC addresses that may be
of MAC address
learned on a VDSL port. For example, if you set this to "5" on port 2, then only the
devices with these five learned MAC addresses may access port 2 at any one
time. A sixth device would have to wait until one of the five learned MAC
addresses aged out. MAC-address aging out time can be set in menu 2. The valid
range is from 0 to 254.
When you have completed this menu, press [ENTER] at the prompt "Press ENTER to Confirm..." to save your
configuration, or press [ESC] at any time to cancel.
16.1.3

Ethernet Port Setup

Ethernet port connections can be half duplex or full duplex. The Ethernet port must use the same speed / duplex
mode setting as the peer Ethernet port in order to connect.
Port Setup
Table 16-1VDSL Port Setup
DESCRIPTION
VES-1000 Series Ethernet Switch
EXAMPLE
Yes
VDSL
10BaseS
Yes
18750K
16667K
No
No
No
0
0
16-3