Chapter 6 Synchronization; Availability Of Synchronous Mode In Control Mode; Synchronous Mode (Dc Mode) - Mitsubishi Electric MELSERVO-JET MR-JET-G-N1 User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET MR-JET-G-N1:
Table of Contents

Advertisement

6
SYNCHRONIZATION
6.1

Availability of synchronous mode in control mode

Availability of synchronous mode (DC mode) and asynchronous mode (Free-run mode) in each mode is shown in the
following table.
Control mode
Cyclic synchronous position mode
Cyclic synchronous position mode (csp)
Cyclic synchronous velocity mode
Cyclic synchronous velocity mode (csv)
Cyclic synchronous torque mode
Cyclic synchronous torque mode (cst)
Homing mode
Homing mode (hm)
*1 If a servo motor is driven with this combination, [AL. 09E.9 Control mode setting warning] will occur.
6.2

Synchronous mode (DC mode)

In the synchronous mode, the synchronous jitter needs to be kept less than 2 μs. If the synchronous jitter is 2 μs or more, an
error may be detected and an alarm may occur.
• Synchronous mode setting
Cycle time
(Obj. 1C32h: 02h)
Shift time
(Obj. 1C32h: 03h)
6 SYNCHRONIZATION
22
6.1 Availability of synchronous mode in control mode
Sync0
0.125 ms (when the PDO communication cycle is set to 0.125 ms)
0.25 ms (when the PDO communication cycle is set to 0.25 ms)
0.5 ms (when the PDO communication cycle is set to 0.5 ms)
1 ms (when the PDO communication cycle is set to 1 ms)
2 ms (when the PDO communication cycle is set to 2 ms)
4 ms (when the PDO communication cycle is set to 4 ms)
8 ms (when the PDO communication cycle is set to 8 ms)
0
Synchronous mode
Asynchronous mode
*1
*1
*1
Sync1
Unused