Power Supply Specifications; Performance Specifications - Mitsubishi Electric MELSEC-FX3S Series Manual

Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
FX
-4AD/FX
-4AD (4-channel Analog Input)
3U
3UC
2.2

Power Supply Specifications

FX
-4AD
3U
Item
A/D conversion
circuit drive power
CPU drive power
FX
-4AD
3UC
Item
A/D conversion
circuit drive power
CPU drive power
2.3

Performance Specifications

Item
Analog input range
*1
Offset
*1
Gain
Absolute maximum
input
Digital output
*4
Resolution
Overall accuracy
Time required for
A/D conversion
Insulation method
Number of I/O
points occupied
*1.
Adjustment of the offset or gain value will not affect the resolution. In the direct indication mode,
however, the offset/gain cannot be adjusted.
*2.
The offset and the gain should satisfy the following condition:
1V ≤ (Gain - Offset)
*3.
The offset and the gain should satisfy the following condition:
3 mA ≤ (Gain - Offset) ≤ 30 mA
*4.
If 1 or more channels use the digital filter(s), the time required for A/D conversion will be
"5 ms × number of selected channels."
PLC User's Manual - Analog Control Edition
24V DC ±10%, 90mA
(It is necessary to supply 24V DC from the terminal block.)
5V DC, 110mA
(Since the internal power is supplied from the main unit, it is not necessary to supply power
externally.)
24V DC ±10%, 80mA
(It is necessary to supply 24V DC from the power connector.)
5V DC, 100mA
(Since the internal power is supplied from the main unit, it is not necessary to supply the power.)
Voltage input
-10V to +10V DC
(Input resistance: 200 kΩ)
-10V to +9V
-9V to +10V
±15V
With sign, 16bits, binary
0.32mV (20V × 1/ 64,000)
2.5mV (20V × 1/8000)
• Ambient temperature: 25°C±5°C
±0.3% (±60mV) for 20V full scale
• Ambient temperature: 0°C to 55°C
±0.5% (±100mV) for 20V full scale
(If 1 or more channels use the digital filter(s): 5ms × number of selected channels)
• The photocoupler is used to insulate the analog input area from the PLC.
• The DC/DC converter is used to insulate the analog input area from the power supply unit.
• Channels are not insulated from each other.
8 points (Taken from either the input or output points of the PLC.)
≤ 7.5V
Specifications
Specifications
Specifications
-20mA to +20mA DC, 4mA to 20mA DC
*2
*2
• Ambient temperature: 25°C±5°C
±0.5% (±200μA) for 40mA full scale
Same accuracy (±200μA) for 4mA to 20mA input
• Ambient temperature: 0°C to 55°C
±1% (±400μA) for 40mV full scale
Same accuracy (±400μA) for 4mA to 20mA input
500μs × number of selected channels
2 Specifications
2.2 Power Supply Specifications
Current input
(Input resistance: 250 Ω)
*3
-20mA to +17mA
*3
-17mA to +30mA
±30mA
With sign, 15bits, binary
1.25μA (40mA × 1/ 32,000)
5.00μA (40mA × 1/8000)
A
B
C
D
E
F
G
H
I
J
B-7