8.3.9

Remote I/O station points setting

The points of each remote I/O station can be set to 8, 16 or 32 points.
This saves the refresh device points of the programmable controller CPU and link refresh time.
The remote I/O station points setting can be used in the remote net ver. 2 mode only.
For parameter setting, use GX Works2.
This function cannot be executed if the dedicated instruction is used for parameter setting. This function can be
executed when read/write from/to the CPU devices is performed according to the I/O points of each station at cyclic
data refresh using the FROM/TO instruction.
Programmable
controller CPU
Master station
Remote output RY
Station
number 2
Station number 3
Y
Set points to even-numbered 8-point setting remote I/O stations consecutively. If points are set to odd-numbered 8-point
setting remote stations, select 8 points + 8 points reserved in the "Remote Station Points" setting of the last of the
consecutive remote I/O stations.
Master station
Remote output RY
Station
number 2
reserved
Station
number 4
8points+8points
(reserved)
Odd-numbered 8-point setting remote stations cannot be set for 8 remote station points.
Master station
Remote output RY
Station
number 2
Station number 4
Cannot be set.
Refer to
188
Remote I/O station
(Station number 1:
Occupies 1 station)
Station
Y07 to Y00
number 1
Station
number 4
to
8-point output module
Device area when remote I/O points setting is made
Device area when remote I/O points setting is not made
Remote I/O station
(Station number 1:
Occupies 1 station)
Station
Y07 to Y00
number 1
Station
number 3
to
8-point output module
Remote I/O station
(Station number 1:
Occupies 1 station)
Station
Y07 to Y00
number 1
Station
number 3
to
8-point output module
Page 77, Section 7.3.2 and Page 99, Section 7.4.2 for the parameter setting.
Remote I/O station
(Station number 2:
Occupies 1 station)
Y07 to Y00
8-point output module
Remote I/O station
Remote I/O station
(Station number 2:
(Station number 3:
Occupies 1 station)
Occupies 1 station)
Y07 to Y00
Y07 to Y00
8-point output module
8-point output module
Remote I/O station
Remote I/O station
(Station number 2:
(Station number 3:
Occupies 1 station)
Occupies 1 station)
Y07 to Y00
Y07 to Y00
8-point output module
8-point output module
Remote I/O station
Remote I/O station
(Station number 3:
(Station number 4:
Occupies 1 station)
Occupies 1 station)
Y0F to Y00
Y0F to Y00
Y1F to Y10
16-point output module
32-point output module
Remote I/O station
(Station number 4:
Occupies 1 station)
Y0F to Y00
Y1F to Y10
32-point output module
Remote I/O station
(Station number 4:
Occupies 1 station)
Y0F to Y00
Y1F to Y10
32-point output module

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-pbtLj61bt11

Table of Contents