11.3 X-RAY GENERATOR
11.3.1
FACTORS
GENERATOR MODEL
Maximum Power (kW)
Maximum mA
Maximum kVp
Power Line
Power Output
(@ 0.1 s)
C
400 / 415 / 440 V~
Three-Phase, 50 / 60 Hz
NOTE: For 1000 mA Generators operating with lines at 400 / 415 / 440 / 480 V~ an auxiliary boost transformer is required
to adequate the line voltage to 530 V~.
11.3.2
RANGE OF RADIOGRAPHIC PARAMETERS
PARAMETER
kVp
mA
mAs
Exposure Time
AEC
AEC
176
SHF-535-1T-LS
SHF-535-1T-HS
RAPIDT
RAPIDT
50 kW
640 mA
150 kVp
C / D
640 mA @ 78 kVp
500 mA @ 100 kVp
400 mA @ 125 kVp
320 mA @ 150 kVp
Three-Phase, 50 / 60 Hz
Line voltage automatic compensation:
Maximum line regulation for maximum kVA demand: 5%
From 10 mA to 1000 mA through the following mA stations:
10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500, 640, 800, 1000
Product of mA x Time values from 0.1 mAs to 500 mAs (640 mAs under request)
From 1 to 10000 milliseconds through the following Time stations:
1, 2, 3, 4, 5, 6, 8, 10, 12, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500, 640,
800, 1000, 1250, 1600, 2000, 2500, 3200, 4000, 5000. 6400, 8000 and 10000
Exposure Time: Nominal shortest irradiation Time = 8.8 ms
SHF-635-1T-HS
RAPIDT
64 kW
640 mA
150 kVp
C / D
640 mA @ 100 kVp
500 mA @ 128 kVp
400 mA @ 150 kVp
POWER LINE
D
480 V~
10%
¦
RANGE
From 40 kVp to 150 kVp in 1 kV steps
(Depending on the Generator model)
mAs: 0.1 mAs to 500 mAs
SHF-835-1T-HS
RAPIDT
80 kW
1000 mA
800 mA
(optional)
150 kVp
C / D
1000 mA @ 80 kVp
800 mA @ 100 kVp
800 mA @ 100 kVp
640 mA @ 128 kVp
640 mA @ 128 kVp
500 mA @ 150 kVp
500 mA @ 150 kVp
E
530 V~
Three-Phase, 50 / 60 Hz
0242F EN 20181218