13. LA40 (MEDLINE
CARELINE
®
Usage
• Duty cycle: 10 %, 2 minutes continuous use, followed by 18 minutes not in use
o
• Usage temperature: 5
C to 40
o
• Storage temperature: -10
C to 50
• Compatibility: Compatible with LINAK control boxes . Please contact LINAK
• Relative humidity: 20% to 80% - non-condensing
• Atmospheric pressure: 700 to 1,060 hPa
• Height above sea level Max . 3,000 meters
• Flammability rating: UL94V-2
• Approvals: IEC 60601-1, ANSI/AAMI ES60601-1, CAN/CSA-C22 .2 No 60601-1
The product is not designed for dynamic load changes (from push to pull or vice versa . If the application design requires a product with a dynamic
load change capability, please contact LINAK for investigation of product feasibility or guidance .
Warning
• The installation of spline actuators is recommended by LINAK where possible to avoid the squeezing of body parts .
• The safety option manual lowering makes it possible to turn the inner tube down by hand in emergency cases or if electrical power is not available .
• Activation of a quick release can lead to a risk of squeezing body parts . Installation of a damper may reduce this risk .
• A quick release can accidentally be activated during mounting or maintenance . To avoid this, operators must be warned before service/mounting .
• End of life issue: defective switches - endstop:
If the electrical endstop switch for outward operation fails, it may cause a prolonged actuator stroke and in addition the customer application may
collapse . To avoid this, the manufacturer must take this into account when designing and making a risk analysis .
• If electrical endstop fails to function the actuator will continue to retract or extend until mechanical endstop is reached . The application of the
customer must be able to obtain or withstand an actuator with failing electrical endstop . Minimum length of actuator reaching mechanical endstop:
BID - 7 mm . Maximum length of actuator reaching mechanical endstop: BID + SL + 7 mm .
• If the actuator does not work as intended, there is a risk of injury . Therefore, the actuator must immediately be sent to the nearest authorised LINAK
workshop for service .
• The actuator is not designed for repeated dynamic push-to-pull movement .
Recommendations
• Power supply without current cut-off can cause serious damage to the actuator if a mechanical stop is encountered or the actuator movement is
blocked in another way .
• Connection bolts must be dimensioned so that they have the necessary strength and tolerance in order to obtain the minimum safety factor according
to the requirements of the authorities .
• The actuator must not be subject to a side load, as this can cause bending/collapse of the actuator . The actuator must never be used as a handle .
• The actuator must not be subject to off-centre loading, as this can cause bending/collapse of the actuator .
• The actuator must not be subject to impact, or any form of stress to the casing .
• The actuator must not be subject to overload, as this can reduce the lifetime of the actuator and in the worst case cause damage to the actuator .
• Only use the actuator within the specifications .
• Connection bolts and brackets are to be inspected in connection with service, and must be replaced if there are signs of wear .
• Ensure that the cable lock is mounted correctly .
• Ensure that the duty cycle and the usage temperatures for LA40 actuators are respected .
• Ensure that the cable cannot be squeezed, pulled or subjected to any other stress .
• The LA40 is not suitable for use in outdoor applications where it can be exposed to sun and rain .
• LA40 with mechanical endstop - a first failure safe option:
In many applications customers have approvals in accordance with EN 60601-1 . The typical applications are beds, massage couches etc . The norm
EN 60601-1 states that the application must be first failure safe . The manufacturer has the responsibility of carrying out a risk analysis in order to
check this . If a risk is identified, the application manufacturer must ensure that this risk is eliminated . A switch cannot be first failure safe .
)
®
o
C
o
C
The LA40 is a low noise and powerful actuator which is available in a 1,500 N,
4,000 N, 6,000 N and an 8,000 N version .
With the LA40, LINAK offers a new durable actuator with high speed/high
performance and mechanical endstop for first failure safety making it the right
choice for the future market . The LA40 versions are rated up to IPX6 Washable
DURA
, except for the LA40 PL version which is rated up to IPX6 .
TM
The LA40 8,000 N is available in three versions:
- Standard
- High Performance (HP)
- Patient Lift (PL)