15. HB190 (MEDLINE
CARELINE
®
Usage
• Operation temperature:
• Storage temperature:
• Relative humidity:
• Operational atmospheric pressure:
• Storage atmospheric pressure:
• Operational meters above sea level: Max . 2000 meters
• Approvals:
• Compatibility:
• Flammability rating:
• Latex free:
Recommendations
• Unless otherwise specified or agreed with LINAK, the hand control is only intended to be used for LINAK systems .
• Inform the customer only to use the magnet key supplied by LINAK .
• It is recommended to make a functional test of the application before setting it into operation .
• Inspect the cable lock before use . If the red indicator is visible, the cable is unsecured . The detachable cables must also be locked .
• In order to maintain the cable flexibility, it is important to place a coiled cable in such a way that its own weight does not strain the coil during the
washing process .
• When changing hand controls for OpenBus™ systems, the power must be switched off .
• Clean the hand control regularly to ensure good hygiene standards .
• It is recommended to check the hand control and cable for damage and holes caused by violent handling before washing the application or at least
once a year .
• Do not submerge the hand control into water .
• Keep the hand control in upright position with the cable downward when washing .
• Does not comply with the 10/15 rule (IEC 60601-2-52:2009 Annex BB . 3 .3 .3)
• Be aware of the current consumption which is 28 mA . With all LEDs lit it will be 65 mA .
LED current consumption:
Red LED
1 .2 mA
Yellow LED
1 .7 mA
Green LED
3 .9 mA
White LED
1 .3 mA
Warnings
• Do not sit or lie on the hand control . It can cause unintended movement of the bed .
• If the hand control shows signs of damage, is dropped or otherwise damaged, the LEDs and backlight might be unfit to use and might show incorrect
information .
• Inform the customer that after loss of mains power, the lock state is reset to the default setting . Be aware of a special setup for a magnet lock of low
power system in case of power down on mains . Also be aware that the lock is reset when running on battery or when powered down .
• Inform the customer that using the magnet key cannot wake up a low-power system or a system running on battery . The system will wake up when
a key is activated .
• Inform the customer that a powerful magnetic field may change the lock state .
• Always use O-ring on connectors and cable locks .
)
®
+5 °C to + 40 °C
-10 °C to + 50 °C
20% to 80% - non-condensing
800 to 1060 hPa
700 to 1060 hPa
IEC60601-1
IEC60601-1-2
All OpenBus
control boxes
TM
UL94 V2
Yes
Page 195 of 295
The HB190 is an advanced hand control designed for high-end medical
equipment . It contains 9 .5 rows, giving the care staff 19 buttons for
activation . It is equipped with 21 LEDs, providing user-friendliness due
to the clear overview of the battery status, locking status and service
indication .
Furthermore, the HB190 comes with an exchangeable cable and is IPX6
Washable DURA™, ensuring a long product lifetime .