11. HB30 (MEDLINE
CARELINE
®
Usage
• Usage temperature: 5 °C to 40 °C
• Storage temperature: -10 °C to +50 °C
• Compatibility: Analogue JUMBO Systems
Analogue JUMBO systems with diode and OpenBus
JUMBO versions
All OpenBus control boxes
CAL40, CAL40+ and COL50
• Approvals: IEC60601-1
ANSI/AAMI ES60601-1
CAN/CSA-22 .2 No 60601-1
The HB30 has a compact design and therefore it cannot be approved according to EN IEC60601-2-52
(Application Environment 4 for care beds used in Domestic areas (or EN1970)) .
How to identify the cables:
Each cable has a label for easy identi-
fication of item number and for which
control box it is intended .
How to remove a cable:
Recommendations
• Please ensure that you use the right cable type to ensure the wished functionality . In case of lack of functionality of your hand control, check that
the hand control cable is the right one for the intended control box or contact your local LINAK representative .
• Please note that HB3X0L0 version (analogue with diode) is not supported by the CBJC . The diode will light up at all times if used with the CBJC .
• Do not submerge the hand control under water .
• Unless otherwise specified or agreed with LINAK, the hand control is only intended to be used on LINAK systems .
• Do not sit or lie down on the hand control . It can cause unintended movement of the application .
• When changing hand controls for OpenBus
• The force of the magnet depends on the thickness and the type of the lacquering, stickers, steel thickness etc . It is the responsibility of the customer
to verify that the holding force on the application is acceptable .
• For hand controls with magnets it is the responsibility of the user/operator to evaluate any possible risk caused by use of permanent magnets .
• For hand controls with magnets it is recommended to have a parking place for the hand control on the application, where the customer ensures that
the hand control does not fall off .
)
®
The HB30 hand control is designed for better user experience and ergonomic fit for the hands
of caregivers . The compact size ensures one hand operation . The HB30 is especially suitable for
patient lifts and other MEDLINE
treatment and examination . The HB30 is available in an analogue version and an OpenBus™
version .
How to mount a cable:
Step 1:
Mount the cable lock and fix it to the
slot marked in the picture .
Step 1:
Release the cable by pushing e .g . a screw-
driver into the hole on the back of the
hand control . Twist and release .
TM
systems, the power must be switched off .
and CARELINE
®
B
A
Step 2:
Fix the cable tab on the hand con-
trol's front side first .
Push in and twist a bit to fix the
tab (see picture fit A into B) .
Page 192 of 295
applications like couches, tables and chairs for
®
Step 3:
Fix the tab on the back as well by
pushing .