21. HL80 (MEDLINE
CARELINE
®
Warnings
• Do not sit or lie on the hand control . It can cause unintended movement of the application .
• When using the locking function on HL80 check that the hand control switches are actually locked .
• Locking function on HL80 only locks the actual hand control .
• Locking of a single channel at HL80 do not neccesarily prevent that channel from activation, if the same channel are covered by another hand control
button (e .g . at simultaneous drive) or another control unit .
• There is a risk that items with internal magnet for mounting instead of hook can disturb function of cardiac pacemaker, implantable cardioverter
defibrillators or magnetic implants! .
Recommendations
• Violent use of the key on HL80 can cause either damage to the keyhole or the key itself .
• If a lock key is missing, then full control over the application could be missing .
• Clean the hand control regularly to ensure good hygiene standards .
• When a defective HL80 is replaced, check that the new HL80 has exactly the same specification and fuctionality .
• Do not submerge the hand control under water .
• Unless otherwise specified or agreed by LINAK, the hand control is only intended to be used on LINAK systems .
• When changing hand controls for OpenBus™ systems, the power must be switched off .
• It is recommended to check the hand control and cable for damage and holes made by violent handling before washing the application or at least
once a year .
• It is recommended to have a parking place for the hand control on the application, where the customer ensures that the hand control does not
fall off .
For hand controls with magnet:
• If hand controls with magnet are attached to a smooth surface, a movement or twisting of the cable, for example during transport, can cause the
hand control to move and result in damage if the cable is squeezed .
• The force of the magnet depends on the thickness of the lacquering, the lacquering type, stickers, steel thickness etc . It is the responsibility of the
customer to verify that the holding force on the application is acceptable .
• It is the responsibility of the user/operator to evaluate any possible risk caused by use of permanent magnets .
22. LS (MEDLINE
CARELINE
®
23. LSD (MEDLINE
CARELINE
®
)
®
The HL80 hand control has an optimised ergonomic design and switch activations .
The HL80 is a lockable hand control, which makes it possible to lock or unlock one or several functions .
It is available in several different standard versions with a variation of bed symbols for easy interaction with
end-users .
Usage
• Approvals: IEC60601-1, ANSI/AAMI ES60601-1 and CAN/CSA-22 .2 No 60601-1
TECHLINE
)
®
®
There are two types of LINAK limit switches, for actuators type LA22, LA30, LA30S , LS, and LSD .
The LS type gives a signal in two fixed end positions, but requires a control unit to stop the actuator when the
microswitches are activated .
TECHLINE
)
®
®
The LSD type controls the stroke length of the actuator between two fixed end positions by cutting off the current
to the motor .