6.5.2.8 DATA All Delete
Purpose
Erases the customer's data in the machine for security reasons when a PWB was replaced, the
machine was removed, etc.
6.5.2.8.1 DATA All Delete (Controller NVM)
Purpose
To initialize the following data that are stored in the ESS/MCU PWB.
•
Job History
Procedure
1.
Enter the CE Diag Mode and input 999-970 in the Chain-Link.
2.
Pressing <Start> displays the initialization confirmation on the UI.
•
To initialize, press <Start> to start the initialization.
•
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
3.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
4.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
6.5.2.8.2 DATA All Delete (Fax NVM)
Purpose
To initialize the following data that are stored in the Fax Kit.
•
Local Terminal Information
•
Telephone Book
•
Jobs Stored for Transmission Information
•
Various Reports
•
Sending Data
•
Receiving Data
•
System Parameter (Default Value for each Market)
Procedure
1.
Enter the CE Diag Mode and input 825-730 in the Chain-Link.
2.
Pressing <Start> displays the initialization confirmation on the UI.
•
To initialize, press <Start> to start the initialization.
•
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
3.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
4.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
Version 1.0
WC 5022/5024
6.5.2.9 Test Pattern Print
Purpose
Performs copy quality check by printing the Test Pattern in the machine.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. of the Test Pattern to print.
NOTE: The 24 Gradation Density Pattern (998-905 and 998-906) can only be output on
A3.
Chain-Link Type
998-901
Blank Image
998-902
Solid black
998-903
Stripe
998-904
Grid Pattern
998-905
24 Gradation Density Pattern
(A3) (ATCN24KED)
998-906
24 Gradation Density Pattern
(A3) (ATCN24KDI)
3.
The default values for the setting screen are - Quantity: 1, Tray 1, and 1 to 1 Sided.
4.
Select the [Quantity], [Paper Supply] and [1 to 2 Sided].
NOTE: The Quantity can be specified up to 2 digits, with the maximum of 99.
5.
Selecting Tray 5 (MSI) displays the [Paper Size] and [Paper Type] settings screen. The
default values for this settings screen are as follows:
•
The values that were set most recently will be displayed.
6.
When the Test Pattern output has completed, [Done] will be displayed.
7.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
06/2014
6-109
Table 1
Overview
Outputs a blank printout.
Outputs a solid black printout.
Outputs a black and white stripes printout.
Outputs a grid pattern printout.
Outputs a 24 gradation density pattern
(ATCN24KED) printout.
Outputs a 24 gradation density pattern
(ATCN24KDI) printout.
6.5.2.8 DATA All Delete