6.5.2.8 DATA All Delete
Purpose
Erases the customer's data in the machine for security reasons when a PWB was replaced, the
machine was removed, etc.
6.5.2.8.1 DATA All Delete (Controller NVM)
Purpose
To initialize the following data that are stored in the ESS/MCU PWB.
Job History
Procedure
1.
Enter the CE Diag Mode and input 999-970 in the Chain-Link.
2.
Pressing <Start> displays the initialization confirmation on the UI.
To initialize, press <Start> to start the initialization.
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
3.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
4.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
6.5.2.8.2 DATA All Delete (Fax NVM)
Purpose
To initialize the following data that are stored in the Fax Kit.
Local Terminal Information
Telephone Book
Jobs Stored for Transmission Information
Various Reports
Sending Data
Receiving Data
System Parameter (Default Value for each Market)
Procedure
1.
Enter the CE Diag Mode and input 825-730 in the Chain-Link.
2.
Pressing <Start> displays the initialization confirmation on the UI.
To initialize, press <Start> to start the initialization.
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
3.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
4.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
Version 1.0
WC 5022/5024
6.5.2.9 Test Pattern Print
Purpose
Performs copy quality check by printing the Test Pattern in the machine.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. of the Test Pattern to print.
NOTE: The 24 Gradation Density Pattern (998-905 and 998-906) can only be output on
A3.
Chain-Link Type
998-901
Blank Image
998-902
Solid black
998-903
Stripe
998-904
Grid Pattern
998-905
24 Gradation Density Pattern
(A3) (ATCN24KED)
998-906
24 Gradation Density Pattern
(A3) (ATCN24KDI)
3.
The default values for the setting screen are - Quantity: 1, Tray 1, and 1 to 1 Sided.
4.
Select the [Quantity], [Paper Supply] and [1 to 2 Sided].
NOTE: The Quantity can be specified up to 2 digits, with the maximum of 99.
5.
Selecting Tray 5 (MSI) displays the [Paper Size] and [Paper Type] settings screen. The
default values for this settings screen are as follows:
The values that were set most recently will be displayed.
6.
When the Test Pattern output has completed, [Done] will be displayed.
7.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
06/2014
6-109
Table 1
Overview
Outputs a blank printout.
Outputs a solid black printout.
Outputs a black and white stripes printout.
Outputs a grid pattern printout.
Outputs a 24 gradation density pattern
(ATCN24KED) printout.
Outputs a 24 gradation density pattern
(ATCN24KDI) printout.