010-379 Fusing Unit Hot Not Ready Return Time Fail
BSD-ON: CH10.2
The High Temperature Not Ready state is not cleared even after the Recovery Time (NVM) has
passed.
Cause/Action
Turn the power OFF and ON. If the problem persists, the Fusing Unit could be malfunc-
tioning.
Replace the Fusing Unit. (PL 7.1)
Version 1.0
WC 5022/5024
010-392 NOHAD Fan Defect
BSD-ON: CH10.3
NOHAD Fan failure was detected. When the NOHAD Fan Fail signal indicating an abnormality
of the Fan was monitored at the specified time interval, it was found to have failed the specified
number of times or higher in a row.
Cause/Action
1.
Check the NOHAD Fan (Output Check [042-002]) for operation failure. (PL 4.1)
2.
Check the NOHAD Fan for foreign substances.
3.
If no problem is found, replace the ESS/MCU PWB (PL 18.3).