REP 17.1.1 Exit Cover

Parts List on PL 17.1
Removal
When turning OFF the power switch, check that the 'Data' lamp is OFF and that there is
no Job in progress.
Turn OFF the power switch and make sure that the screen display turns OFF.
Check that the power switch is OFF and unplug the power plug.
1.
Remove the Drum Cartridge. (REP 8.1.1)
2.
Remove the Toner Cartridge. (PL 8.1)
3.
Remove the Front Cover. (REP 19.1.1)
4.
Remove the Fusing Unit. (REP 7.1.1)
5.
Remove the Top Cover. (REP 19.1.2)
6.
Remove the Exit Cover. (Figure 1)
a.
Remove the screw.
b.
Release the hook (x6).
c.
Remove the Exit Cover.
Figure 1 j0lj41701
Reference: This shows the removed Exit Cover. (Figure 2)
Version 1.0
WC 5022/5024
WARNING
Replacement
1.
To install, carry out the removal steps in reverse order.
2.
When installing the Exit Cover, insert the boss of the Exit Cover into the hole of the
Frame. (Figure 3)
06/2014
4-59
Figure 2 j0lj41702
Figure 3 j0lj41705