IDS2 Strobing (27mm or 13.5mm Pitch Density)

Figure 1 Strobing (27 mm or 13.5 mm Pitch Density) Defect Sample (j0ch3218)
Cause
1.
Developer Magnetic Roll bias.
Action
1.
Replace the Drum Cartridge (PL 8.1) (REP 8.1.1)
Version 1.0
WC 5022/5024

IDS3 White Streaks (Process Direction)

Figure 1 White Streaks (Process Direction) Defect Sample (j0ch3219)
Cause
1.
Foreign substances are blocking the ROS Laser.
2.
Developing powder clogging on the Developer Magnetic Roll due to foreign substances.
Action
1.
Clean the light path and the seal glass between the ROS Assembly (PL 2.1) (REP 2.1.1)
and the Drum Cartridge (PL 8.1) (REP 8.1.1).
2.
Replace the Drum Cartridge (PL 8.1) (REP 8.1.1)
06/2014
IDS2 Strobing (27mm or 13.5mm Pitch Density)
3-15
Image Quality Troubleshooting