Chain-Link NVM Name
742-014
PH_LEAD_REGI_THICK2_TRAY1
742-015
PH_LEAD_REGI_THICK2_TRAY2
742-016
PH_LEAD_REGI_THICK2_TRAY3
742-017
PH_LEAD_REGI_THICK2_TRAY4
742-018
PH_LEAD_REGI_THICK2_MSI
742-019
PH_LEAD_REGI_THICK2_DUPLEX
742-020
PH_REGI_LOOP_ALL_TRAY
742-021
PH_REGI_LOOP_TRAY1
742-022
PH_REGI_LOOP_TRAY2
742-023
PH_REGI_LOOP_TRAY3
742-024
PH_REGI_LOOP_TRAY4
742-025
PH_REGI_LOOP_MSI
742-026
PH_REGI_LOOP_DUPLEX
742-027
PH_REGI_LOOP_THICK1_TRAY1
General
6.3.9.2 NVM PH
Table 1 NVM PH
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
-50
50
0
06/2014
6-52
Write Yes/
Initializatio
No
n Yes/NO
Discription
Disable
Enable
TRAY1 for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY2 for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY3 for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY4 for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
SMH for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
DUP ALL SIZE for thick2 LEAD REGI ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
REGI LOOP ADJUSTMENT - ALL TRAY
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY1 for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY2 for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY3 for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY4 for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
SMH for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
DUP ALL SIZE for Normal REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)
Disable
Enable
TRAY1 for thick1 REGI LOOP ADJ
Image input is delayed when Set Value is increased.
(Unit: 2 ms)