116-323 Controller NVM Data Defect
BSD-ON:-
Any of the following was detected:
•
The On Board NVM data of the Controller is corrupted.
•
The On Board NVM of the Controller is not installed.
•
Any one of the Print Counter has reached its maximum value.
•
The number of times the NVM can be changed has reached its limit.
NOTE: If this Fault reoccurs after performing Data Backup/Restore, perform Data Restore
again. (Perform NVM Matching (NVM [621-400]) in the CE Mode.)
Cause/Action
1.
Turn the power OFF and ON.
2.
Perform NVM Initialize in the CE Mode. (Refer to 6.5.2.4 NVM Initialize)
Status Indicator RAPs
116-323 Controller NVM Data Defect
116-324 Exception Fail
BSD-ON:-
The CPU has rebooted due to the occurrence of an exception.
Cause/Action
Upgrade the Controller software or contact the Support Department.
06/2014
2-142
Version 1.0
WC 5022/5024