6.3.4.5 IOT HFSI List - System Administrator Mode Version
Purpose
This provides a function to initialize the HFSI Counter and Replacement Flag in the System
Administrator Mode, which is limited to the Periodic Replacement Parts that a User can
replace.
Procedure
1.
Enter the System Administrator Mode.
a.
Press <Log In/Out> for 4 seconds or longer.
b.
Use the keypad to enter the Password [11111] *1 and select [OK].
NOTE: *1 Default Value
2.
Use <Up>/<Down> to select [System Settings] and then select [OK] or [->].
3.
Use <Up>/<Down> to select [Maintenance] and then select [OK] or [->].
4.
Input the following number for the applicable parts and then press <Start> to display the
[Part Name] and [Current Value]. Pressing <Start> again clears the counter.
Table 1
Number
Component Name
950800
X'fer (BTR Unit)
950801
Fusing Unit Assy
950802
MSI Feed
950803
Tray 1 Feed
950804
Tray 2 Feed
950805
Deodorant Filter
950806
VOC Filter
950807
Drum Cartridge
950808
Tray 3 Feed
950809
Tray 4 Feed
752133 *1
Manual Toner Change
*1: 752133 is not an HSFI Counter. It is something used for clearing the Replacement
Flag in the event of a replacement. The Current Value displays '0'.
5.
Check the value using Step 4 as needed.
6.
Exit from the System Administrator Mode.
a.
Press <Log In/Out>. *2
*2: If any of the above parts had been cleared, the machine will reboot upon exiting from
the System Administrator Mode.
General
6.3.4.5 IOT HFSI List - System Administrator Mode
06/2014
6-34
Version 1.0
WC 5022/5024