Xerox WorkCentre 5022 Service Manual page 459

Hide thumbs Also See for WorkCentre 5022:
Table of Contents

Advertisement

6.3.4.1 DADF HFSI List
Chain-Link
Content Name
955-806
Document Feed
(CVT DADF machine)
955-807
Document Feed Simp
(CVT DADF machine)
955-808
Document Feed Dup
(CVT DADF machine)
955-810
Platen Open/Close Count
(CVT DADF machine)
955-812
Takeaway Clutch ON Count
955-826
Nip Release Solenoid ON Count
955-828
Feed Clutch ON Count
6.3.4.2 IIT HFSI List
Chain-Link Content Name
956-802
IIT Scan
956-803
Lamp ON Time
956-804
Lamp ON Count
956-808
Platen I/L Open Count
Version 1.0
WC 5022/5024
Table 1 DADF HFSI List
Life Value
Setting Range
200,000
0~5,000,000
360,000
0~5,000,000
360,000
0~5,000,000
180,000
0~1,000,000
1,080,000
0~1,000,000
500,000
0~1,000,000
360,000
0~1,000,000
Life Value
Setting Range
Count Condition
-
0~6,881,175
Scan Count (including pre-Scan)
Counts up with each scan
HFSI -> Scan count after clearing HFSI Counter
Recycle -> Total Scan count without clearing
To clear the counter, enter the HFSI Counter Read / Clear Mode
and select [Clear] -> [Start] to clear it to '0'.
-
0~7,864,200
Lamp ON Time
Starts timing when the lamp turns ON
Stops timing when the lamp turns OFF
Writes to the NVM during CRG Initialize
HFSI -> Lamp ON time after clearing HFSI Counter
Recycle -> Total Lamp ON time without clearing
To clear the counter, enter the HFSI Counter Read / Clear Mode
and select [Clear] -> [Start] to clear it to '0'.
-
0~6,881,175
Lamp ON count after clearing HFSI Counter
Counts up when the lamp turns ON
Writes to the NVM during CRG Initialize
To clear the counter, enter the HFSI Counter Read / Clear Mode
and select [Clear] -> [Start] to clear it to '0'.
-
0~1,966,050
Counts up at every detection of the full open status of the Angle
Sensor.
Count Condition
Counts up when the Feed Sensor turns ON
HFSI -> Document Feed count after clearing HFSI Counter
Recycle -> Total Document Feed count without clearing
To clear the counter, enter the HFSI Counter Read / Clear Mode and
select [Clear] -> [Start] to clear it to '0'.
Counts the no. of document sheets fed in Simplex mode
To clear the counter, enter the HFSI Counter Read / Clear Mode and
select [Clear] -> [Start] to clear it to '0'.
Counts the no. of document pages fed in Duplex mode
To clear the counter, enter the HFSI Counter Read / Clear Mode and
select [Clear] -> [Start] to clear it to '0'.
Counts up when the Platen Interlock opens
To clear the counter, enter the HFSI Counter Read / Clear Mode and
select [Clear] -> [Start] to clear it to '0'.
Counts up at Takeaway Clutch On
Counts up at Nip Release Solenoid On
Counts up at Feed Clutch On
Table 1 IIT HFSI List
06/2014
6-31
Description
No. of sheets fed from the CVT
Tray
The NVM is controlled by the CVT
The NVM is controlled by the CVT
* Life is common to 955-808
The NVM is controlled by the CVT
* Life is common to 955-807
The NVM is controlled by the CVT
The NVM is controlled by the CVT
The NVM is controlled by the CVT
The NVM is controlled by the CVT
Description
The NVM Write timing is T.B.D.
1 time increments
Max count value = 6,000,000 times and above
Only count Platen Scans, not CVT Scans
Lamp Life 2000 hours
1 second increments
Max count value = 7,200,000 s and above
Counts the total duration when the lamp is ON
(including AGOC, LampCheck).
Lamp Life 6,000,000 times
1 time increments
Max count value = 6,000,000 times and above
Counts the no. of times the lamp turns ON
(including AGOC, LampCheck).
Count increment: 1 timeMax count value:
1000K times or more
General
6.3.4.1 DADF HFSI List