6.5.2.7 HFSI Counter Clear/Initialize
Purpose
Clears and initializes the HFSI Counter that is used as the guideline for replacement of con-
sumables.
6.5.2.7.1 HFSI Counter Clear
Purpose
To clear the HFSI Counter.
NOTE: For more details on the HFSI Counter Code, refer to 6.3.4 in Chapter 6.
You can reference the [Maintenance Report] in KO Mode.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press <Start>.
3.
The read value of the HFSI Counter for the monitored component is displayed on the UI.
4.
Pressing <Clear (C)> and then <Start> clears the read value of the HFSI Counter to '0'.
5.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
6.5.2.7.2 HFSI Counter Initialize
Purpose
To initialize the HFSI Counter.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. of the item to initialize.
Chain-Link Type
998-982
Initialize HFSI Counter
998-983
Initialize HFSI Counter-IIT
998-984
Initialize HFSI Counter-MCU
998-985
Initialize HFSI Counter-DADF Clears all the DADF-related HFSI Counters at
3.
Pressing <Start> displays the initialization confirmation on the UI.
To initialize, press <Start> to start the initialization.
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
General
6.5.2.7 HFSI Counter Clear/Initialize
Table 1
Overview
Clears all the HFSI Counters at one go.
Clears all the IIT-related HFSI Counters at one
go.
Clears all the MCU-related HFSI Counters at one
go.
one go.
4.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
5.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
06/2014
6-108
Version 1.0