Rep 6.1.1 Btr Roll - Xerox WorkCentre 5022 Service Manual

Hide thumbs Also See for WorkCentre 5022:
Table of Contents

Advertisement

REP 6.1.1 BTR Roll

Parts List on PL 6.1
Removal
When turning OFF the power switch, check that the 'Data' lamp is OFF and that there is
no Job in progress.
Turn OFF the power switch and make sure that the screen display turns OFF.
Check that the power switch is OFF and unplug the power plug.
1.
Open the L/H Cover.
2.
Remove the BTR Roll. (Figure 1)
a.
Release the hook (x4) of the bearing.
b.
Remove the BTR Roll.
Figure 1 j0lj40601
Reference: This shows the removed BTR Roll. (Figure 2)
Version 1.0
WC 5022/5024
WARNING
NOTE: As the bearing is not secured to the BTR Roll, be careful so as not to allow it to
drop.
Replacement
1.
To install, carry out the removal steps in reverse order.
2.
After a replacement, enter the Diag Mode and use [Initialize HFSI Counter] to clear the
HFSI counter.
"Chain Link : 950-800"
Refer to [6.5.2.7 HFSI Counter Clear / Initialize].
06/2014
4-23
Figure 2 j0lj40602