077-905 Feed Out Sensor 3 Static Jam
BSD-ON: CH8.3
Feed Out Sensor 3 On was detected during Standby.
Initial Actions
Refer to the BSD and check the related connectors of the target electrical parts for partial con-
nections.
Cause/Action
Check the following:
•
The Feed Out Sensor 3 for remaining paper, Actuator return failure, foreign substances,
contamination on sensor, and etc.
•
Feed Out Sensor 3: Input Check [072-109] (PL 11.5)
If no problems are found, replace the 2TM PWB (PL 11.6).
Version 1.0
WC 5022/5024
077-906 Feed Out Sensor 4 Static Jam
BSD-ON: CH8.3
Feed Out Sensor 4 On was detected during Standby.
Initial Actions
Refer to the BSD and check the related connectors of the target electrical parts for partial con-
nections.
Cause/Action
Check the following:
•
The Feed Out Sensor 4 for remaining paper, Actuator return failure, foreign substances,
contamination on sensor, and etc.
•
Feed Out Sensor 4: Input Check [072-112] (PL 11.5)
If no problems are found, replace the 2TM PWB (PL 11.6).
06/2014
077-905 Feed Out Sensor 3 Static Jam
2-129
Status Indicator RAPs