Xerox WorkCentre 5022 Service Manual page 475

Hide thumbs Also See for WorkCentre 5022:
Table of Contents

Advertisement

6.3.8.2 NVM DRIVE & NOHAD
Chain-Link NVM Name
740-001
DRV_MAIN_MOTOR_SPEED
740-002
DRV_MAIN_MOTOR_BRAKE_SWITCH
741-001
NOHAD_PRINT_STOP_DELAY
741-002
NOHAD_STBY_MODE_INTVAL
741-003
NOHAD_STBY_MODE_COUNT_THRESHOL
D
741-004
NOHAD_STBY_MODE_TEMP_THRESHOLD 0
741-005
NOHAD_STBY_MODE_SWITCH
741-006
NOHAD_COLD_MODE_TEMP_THRESHOLD 0
741-007
NOHAD_COLD_MODE_HOLD_TIME
741-026
NOHAD_CONDENSE_SWITCH
741-027
NOHAD_CONDENSE_ENTRY_TEMP_THRE
SHOLD
741-028
NOHAD_CONDENSE_HOLD_TIME
741-029
NOHAD_SMELL_FILTER_SWITCH
741-031
NOHAD_FAN_FAIL_START_TIMER
741-032
NOHAD_FAN_FAIL_SUMPLE_TIME_THRES
HOLD
Version 1.0
WC 5022/5024
Table 1 NVM DRIVE & NOHAD
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
1040000
1562000
1496201
0
1
0
15
1800
15
1
20
1
1
20
3
800
245
0
1
1
300
140
0
180
0
0
1
0
0
300
120
0
240
90
0
1
0
0
60
6
10
300
48
06/2014
6-47
Write Yes/
Initialization
No
Yes/No
Description
Disabled
Enabled
main motor speed
(Unit: Ref CLK)
Disabled
Enabled
Main motor brake signal switch
0: Main motor brake signal invaild1: Main motor brake sig-
nal effective
Disabled
Enabled
The time for Fan high speed rotation after printing has
completed.
(Unit: 1 s)
Disabled
Enabled
The temperature sampling time for Fusing Fan Tempera-
ture Control.
(Unit: 1 s)
Disabled
Enabled
The threshold count for determining the mode transition of
the Fusing Fan Temperature Control.
(Unit: 1 time)
Disabled
Enabled
The threshold temperature for determining the mode tran-
sition of the Fusing Fan Temperature Control.
(Unit: 0.1 Degrees Celsius)
Disabled
Enabled
Fusing Fan Temperature Control Execution Switch
0: Do not perform, 1: Perform
Disabled
Enabled
The threshold temperature for determining the Fan Low
Temperature Stop Operation.
(Unit: 0.1 Degrees Celsius)
Disabled
Enabled
The time to maintain the Fan in low speed rotation for Fan
Low Temperature Stop Operation.
(Unit: 1 s)
Disabled
Enabled
Condensation Mode Execution Switch.
0: Do not perform, 1: Perform
Disabled
Enabled
The threshold temperature for determining whether to tran-
sition to the Condensation Mode.
(Unit: 0.1 Degrees Celsius)
Disabled
Enabled
The time where the transition to the Sleep Mode is prohib-
ited after entering the Condensation Mode.
(Unit: min)
Disabled
Enabled
Deodorant Filter Availability Switch.
0: No Deodorant Filter, 1: Deodorant Filter available
Disabled
Enabled
The time where Fail Detection is prohibited after the Fan
operation.
(Unit: 1 s)
Disabled
Enabled
Fan Fail Signal Accumulated Time.
(Unit: 1 s)
General
6.3.8.2 NVM DRIVE & NOHAD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: