6.5.2.1 Shutdown History
Purpose
Initialize the Fault History.
You can reference the [Error History Report] in KO Mode.
Overview
The Chain-Link, type, and overview for the Shutdown History are as follows.
Chain-Link Type
998-980
Initialize Fault History
6.5.2.1.1 Initialize Fault History
Purpose
Initializes the Fault History (without Jam/Jam).
Procedure
1.
Enter the CE Diag Mode and input 998-980 in the Chain-Link.
2.
Pressing <Start> displays the initialization confirmation on the UI.
To initialize, press <Start> to start the initialization.
To cancel initialization, press <Clear (C)> to return to the [Diagnostics Mode Base]
screen.
3.
Perform the initialization. When the initialization has completed, [Done] will be displayed.
4.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.
Version 1.0
WC 5022/5024
Table 1
Overview
Initialize the Fault History.
6.5.2.2 NVM Read / Write
Purpose
Refers to the NVM data or changes setting value.
NOTE: For details on NVM No. (Chain-Link), refer to 6.3.5 until 6.3.21 in Chapter 6.
Procedure
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press <Start>.
NOTE: E.g.) The machine does not accept [700-6] as an abbreviation of [700-006]. When
a number starts with '0', the '0' must be input.
3.
The current NVM setting value is displayed.
4.
For an NVM that can have its setting value changed, use the keypad to input the setting
value and press <Start>.
The value that was input can be cleared by pressing <Clear (C)>.
To input a negative number, insert '*' at the beginning of the input.
NOTE: If an invalid value was input, an [Error] screen will be displayed. Press <Clear
(C)> to return to the [Diagnostics Mode Base] screen.
5.
The changed NVM setting value is displayed.
6.
Pressing <Clear (C)> returns you to the [Diagnostics Mode Base] screen.