ADJ 18.1.2 IOT Lead Edge/Side Edge Registration

Purpose
To align the image on the drum with the proper position (Lead/Side Edge) of the paper.
Check
1.
Load A4 paper into the Tray in SEF orientation.
2.
Enter the CE Mode and input 999-980 (Maintenance Report) in the Chain-Link.
3.
Pressing <Start> prints the Maintenance Report.
4.
Measure the Lead and Side Edges of the print pattern.
Lead Edge: Part A of the pattern
Side Edge: Part B of the pattern
Figure 1 j0lj41895
5.
Check that the measured values of the Lead Edge (A) and Side Edge (B) fall within the
corresponding specifications.
NOTE: To perform measurement for the Lead Edge (A) and Side Edge (B) of Duplex
printouts, load the Maintenance Report that was output on the Platen, and make a 1 -> 2
Sided copy to perform the measurement.
Table 1 IOT Lead Edge/Side Edge
Item
Simplex
Duplex
Lead Edge
30 +/-2.4
30 +/-3.4
(A)
mm
mm
Side Edge (B) 30 +/-3.0
30 +/-3.4
mm
mm
Adjustment
1.
Enter the CE Mode.
2.
Adjust the NVM until each measured value of the Lead Edge (A) and Side Edge (B) fall
within the specifications of the corresponding mode.
Version 1.0
WC 5022/5024
MSI
STM (TTM)
30 +/-3.1
30 +/-3.1
mm
mm
30 +/-3.2
30 +/-3.0
mm
mm
If the measured value is short: Set a larger value.
If the measured value is long: Set a smaller value.
Chain-
Link
Name
742-001 PH_LEAD_REGI_ALL_TRAY
742-002 PH_LEAD_REGI_TRAY1
742-003 PH_LEAD_REGI_TRAY2
742-004 PH_LEAD_REGI_TRAY3
742-005 PH_LEAD_REGI_TRAY4
742-006 PH_LEAD_REGI_MSI
742-007 PH_LEAD_REGI_DUPLEX
749-001 ROS_LASER_SIDE_REGI_ADJUSTMENT_ALL_TRAY -50
749-002 ROS_LASER_SIDE_REGI_ADJUSTMENT_TRAY 1
749-003 ROS_LASER_SIDE_REGI_ADJUSTMENT_TRAY 2
749-004 ROS_LASER_SIDE_REGI_ADJUSTMENT_TRAY 3
749-005 ROS_LASER_SIDE_REGI_ADJUSTMENT_TRAY 4
749-006 ROS_LASER_SIDE_REGI_ADJUSTMENT_MSI
749-007 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_ALL_
TRAY
749-008 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_TRA
Y 1
749-009 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_TRA
Y 2
749-010 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_TRA
Y 3
749-011 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_TRA
Y 4
749-012 ROS_LASER_SIDE_REGI_ADJUSTMENT_DUP_MSI
3.
After adjustment, print the Maintenance Report in the same mode again.
4.
Repeat the procedure until the measured values of the Lead Edge (A) and Side Edge (B)
fall within the specifications.
06/2014
4-101
Table 2 NVM List
Initi
Min
al
-50
0
-50
0
-50
0
-50
0
-50
0
-50
0
-50
0
0
-50
0
-49
0
-49
0
-49
0
-50
0
-50
0
-50
0
-50
0
-50
0
-50
0
-50
0
Repairs and Asdjustments
Max Step
50
2 ms
50
2 ms
50
2 ms
50
2 ms
50
2 ms
50
2 ms
50
2 ms
50
0.254
mm
50
0.254
mm
49
0.254
mm
49
0.254
mm
49
0.254
mm
50
0.254
mm
50
0.254
mm
50
0.254
mm
50
0.254
mm
50
0.254
mm
50
0.254
mm
50
0.254
mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5024

Table of Contents