Model name
Power source
Available voltage range
Cooling
Capacity
Heating
Input power
Static pressure range
Standard static pressure
Airflow rate
Fan
Type × Quantity
Motor output
High
Me-Hi
Med
Sound pressure
level
Lo-Hi
Low
Quiet
Length
Fin pitch
Rows × Stages
Face Area
Heat exchanger
Pipe type (Material)
Fin
Type
Air filter
Net material
Material
Enclosure
Colour
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Liquid (Flare)
Connection
Gas (Flare)
pipe diameter
Drain hose
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
ARXK14GCLH
4.5
kW
5.0
W
Pa
Pa
760
High
(211)
660
Me-Hi
(183)
560
Med
(156)
3
m
/ h
(l / s)
490
Lo-Hi
(136)
410
Low
(114)
340
Quiet
(94)
Sirocco × 2
W
dB(A)
490
mm
2
m
0.16
Type (Material)
Surface
treatment
198 × 700 × 450
mm
250 × 930 × 580
kg
ø 6.35
mm
ø 12.70
- (04-11) -
ARXK18GCLH
230 V ~ 50 Hz
198 to 264 V
5.6
6.3
66
73
0 to 50
15
930
(258)
840
(233)
740
(206)
640
(178)
540
(150)
470
(131)
Sirocco × 3
80
34
33
31
30
28
28
26
26
24
24
22
22
690
1.30
2 × 16
0.23
Grooved H-pin (Copper)
Slit (Aluminium)
Hydrophilic coating
Fungicide type
PP honeycomb
galvanized sheet iron
-
198 × 900 × 450
250 × 1,130 × 580
16
19
19
22.5
VP25 [ø 25(I.D.) ; ø 32(O.D.)]
ARXK24GCLH
7.1
8.0
80
1,160
(322)
1,060
(294)
960
(267)
860
(239)
750
(208)
610
(169)
Sirocco × 4
81
32
30
28
27
25
22
890
0.30
198 × 1,100 × 450
250 × 1,330 × 580
22.5
26
ø 9.52
ø 15.88