Configure Digi Connect Sensor+ device settings
7. In the search field, append the device ID with a battery data point:
/ts1/bat: Reports the percentage of remaining battery life.
n
/ts1/abt: Reports the battery life threshold percentage setting.
n
8. Click the magnifying glass icon. The specified data streams appear.

Configure internal temperature settings

The Digi Connect Sensor+ internal temperature is included as a report in Remote Manager data
streams. Configure internal temperature alarms so that Digi Connect Sensor+ sends alarm reports for
high temperatures, low temperatures, and unusual temperature changes. For details about these
options, see
Internal Temperature option
CAUTION! If Digi Connect Sensor+ sends reports less than 15 minutes apart, it may
result in an internal temperature that is above the ambient temperature.
To configure global alarm options:
1. Sign in to
Remote
2. Click the arrow next to your user name and choose Open Classic Remote Manager.
3. Click Device Management > Devices tab.
4. Double-click the Digi Connect Sensor+ device you want to configure.
5. Expand the Configuration menu.
5. Click Internal Temperature.
6. Select On for Interface Enable to turn on this option.
7. Enter appropriate values for each option. Threshold and hysteresis values are in Celsius.
8. Apply the configuration changes:
a. Click Save > Schedule. The Save Device Properties dialog appears.
b. Select Immediate.
c. Select Schedule Offline.
d. Click Schedule. Digi Connect Sensor+ downloads and applies configuration changes
Configure local interface settings: CLI and Bluetooth
Enable or disable the CLI or Bluetooth for Digi Connect Sensor+ through the Local Interface Settings
option. For details about these options, see
Note
Digi recommends that you keep the local interface settings enabled.
To configure local interface settings:
1. Sign in to
Remote
2. Click the arrow next to your user name and choose Open Classic Remote Manager.
Digi Connect Sensor+ User Guide
definitions.
Manager.
the next time it connects to Remote Manager.
Local Interface Settings option
Manager.
Configure internal temperature settings
definitions.