Analog and digital power output CLI commands

Use the commands in the following table with the set command and the sensor power identifier when configuring the sensor options with the CLI. For
example, type set avout1 ena=on to enable the analog power output 1 interface.
Sensor power identifiers:
Analog power output 1: avout1
n
Analog power output 2: avout2
n
Analog power output 3: avout3
n
Analog power output 4: avout4
n
Digital power output: dvout1
n
Option
CLI command
Power output
ena
interface
Output level
out
Read delay
rdl
Description
Enables or disables the power output source.
Specifies the voltage level output for the analog power source.
Specifies the time in seconds that the sensor voltage is enabled before
Connect Sensor reads its value. This allows the sensor to stabilize to
get an accurate reading.
Note
A higher read delay keeps the device powered on longer, which
reduces battery life.
Value options
Default
off
on
n
off
n
3.3
3.3
n
5
n
15
n
24
n
0-120 seconds
0