Servo System With Auxiliary Equipment - Mitsubishi Electric MELSERVO-J2-Super Series Supplementary Instructions Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

2. MR-J2S-
A4 SERVO AMPLIFIER

2.4 Servo system with auxiliary equipment

WARNING
(1) MR-J2S-200A4 or less
3-phase
380 to 480VAC
power supply
No-fuse
breaker
(NFB) or
fuse
Magnetic
contactor
(MC)
Power
factor
improving
reactor
(FA-BAL)
L
1
L
2
L
3
P
Regenerative
option
C
U
V
W
To prevent an electric shock, always connect the protective earth (PE) terminal
(terminal marked
) of the servo amplifier to the protective earth (PE) of the
control box.
Options and auxiliary equipment
No-fuse breaker
Magnetic contactor
MR Configurator
(Servo configuration software)
Reference
Options and auxiliary equipment
Section 6.2.2
Regenerative option
Section 6.2.2
Cables
MR-J2S-
A
Power factor improving reactor
Servo
Amplifier
Instruction
Manual
To CN1A
To CN1B
To CN3
Circuit protector
24V L
11
0V
L
21
To CN4
To CN2
Servo motor
HC-SFS 400V series
2 - 9
Reference
Section 6.1.1
Section 6.2.1
Section 6.2.3
Command
device
Junction
terminal block
MR Configurator
(Servo configuration
Personal
software MRZJW3-
computer
SETUP151E)
24VDC
Power
supply

Advertisement

Table of Contents
loading

Table of Contents